View Drive Manual PDF
Input Voltage VAC:
115 or 230 Single Phase
HP Rating 230V 1/6 to 1
Output Current AMPS 4.0
Output Frequency 0-120 Hz |
NEMA 4X Enclosure
Compact, easy to mount, black plastic enclosure.
Isolated Inputs: Accepting floating or grounded signals 0-10VDC,
0-5VDC or 4-20 mA.
User Adjustable Calbration pots: Minimum speed, maximum speed, current
limit, acceleration, deceleration, slip compensation, boost, sero set,
brake current, and brake time.
Diagnostic LED's: Power, fault, and torque limit.
Stopping Modes: DC injection braking or coast. (jumper schedule)
Switching Frequency: Adjustable 4 to 16 kHz switching frequency; Quiet
motor operation or reduced electrical noise.
Quick Disconnect Terminal Block: Allows up to 200% torque to overcome
intermittent peak loads.
Additional Features: Auto or manual restart after low input voltage
fault ( jumper selectable), line fusing, enable and direction inputs.
|

View Drive Manual PDF Input Voltage VAC:
115 or 230 Single Phase
HP Rating 230V 1/6 to 1/2
Output Current AMPS 2.4
Output Frequency 0-120 Hz |
| The cost-conscious and compact chassis design of Bison
VFD Chassis Drives maintain the industry standard for
mounting hole location and the coded LEDs make it easy to
visually determine the drive status. With it's compact
design and application flexibility, this is an excellent
choice for most AC applications. |
Compact Size: 4.3" x 3.7"...Easy to mount in small
spaces with industry standard mounting hole pattern.
Easy to Calibrate and Set-up: On board trimmer pot
adjustments for boost, maximum speed, acceleration, and
deceleration.
Torque "Foldback" Feature: Allows up to 200% torque for
short periods to overcome intermittent peak loads, then
reduces the torque to a preset safe level.
Switching Frequency: 16 kHz switching frequency, with
option to change between 4 and 16 kHz in the field. A high
switching frequency results in quiet motor operation.
Adjustments to a lower frequency if desired can be done in
the field. |
|
|
|