NEMA 1 Enclosure |
Description |
Dimensions
Cross Reference |
Part # |
Cost |
|
1.5 hp 115 Volt Single Phase
2 hp 230 Volts Single Phase
Single Phase Only
View Wiring Diagram |
Dimensions:
W: 2.25" H: 4.5" D: 4"
|
| Position = Maintained |
RS-1A |
$39.95 |
|
Position = Spring Returned
Operation = Spring Return to Center |
RS-1A-MP |
$44.98 |
|
Dayton- 2X440
McMaster Carr - 7065K21
GE - CR 102 A2
Square D - AG-2 |
1.5 hp 115 Volt Single Phase
2 hp 230 Volts Single Phase
2 hp 230 Volts Three Phase
1 hp 460 Volts Three Phase
View
Wiring Diagram |
Dimensions:
W: 2.25" H: 4.5" D: 4"
Position = Maintained |
| Position = Maintained |
RS-1 |
$48.98 |
|
Position = Spring Returned
Operation = Spring Return to Center |
RS-1M |
$50.95 |
|
Dayton - 2X441
McMaster Carr - 7065K23
Cutler Hammer - H-268
Furnas - R-44
GE - CR 102 A1
Square D - AG-2 |
1.5 hp 115 Volt Single Phase
2 hp 230 Volts Single Phase
2 hp 230 Volts Three Phase
2 hp 460Vvolts Three Phase
View Wiring Diagram |
Dimensions:
W: 3.5" H: 5.5" D: 5"
Position = Maintained
not UL/CSA rated |
RS-2 |
$78.95 |
|
Dayton - 2X442
McMaster Carr - 7065K24
Cutler Hammer - H-353
Furnas - J-2 |
2 hp 115 Volts Single Phase
3 hp 230 Volts Single Phase
5 hp 230 Volts Three Phase
7.5 hp 460 Volt Three Phase
View Wiring Diagram |
Dimensions:
W: 3.5" H: 5" D: 6.5"
Position = Maintained |
RS-5 |
$102.89 |
|
Dayton - 2X443
McMaster Carr - 7065K25
Cutler Hammer H-284
Furnas - J-5
Square D - BG-1 |
|

NEMA 4X Enclosure
Water Tight |
1.5 hp 115 Volt Single Phase
3 hp 230 Volts Single Phase
------------------------------------------------------Stainless steel cover screws, shaft, springs, switch mounting screws, and corrosion-resistant
plated switch terminal screws. Include two watertight cable connectors and two decals: Fwd Off Rev/Up Off Down.
Wiring Diagram |
Dimensions:
W: 3.7" H: 4.7" D: 3.1"
Position = Momentary
Operation = Spring Return to Center
Inductive Current 20 Amps
Advance Controls #
CW0177860S35
Dayton - 6C014 |
CW0177860S35 |
$108.95 |
|
Note: We recommend this control only be installed by a qualified technician that understands how electric motors are
wired. Motor must have wire leads for connections. If motor only has a terminal board it will be very difficult to wire the switch. This
installation would most likely require a skilled electric motor technician.
Single Phase Wire Code Legend
for motors with wire colored leads.
May not relate to the wire colors
on a terminal board. |
Blue = T1
White = T2
Orange = T3
Yellow = T4
Red = T8
Black = T5 |
|
|